Just released Aug 23-2024
REC Active 2.9.4 BMS release Notes
- A separate BIN file for dual bus systems is no longer required, parameter MODE 1 is UV and OV, While MODE 2 is only UV controlled by the MAIN relay. So the CHARGE relay should be configured using TASKS in the WiFi.
- We have added 2 RS485 bitrates 56k and 115k2 so it displays faster. This is changed by RSBR 1 as 56k and RSBR 2 for 115k2. Reacts immediately without restart.
- NOW CANS is used instead of CANF so it is the same as for 2Q BMS. USer can set it from 100k to 1M CAN2.0A and CAN2.0B (29-bit ID) Reacts immediately without restart.
- CAN response is a bit faster and it has
- better tapering of voltage controlled end of charge.
- If the BMS signals ERROR 14, the end number displays error setting position, so the user can see the problematic parameter